Synthes tfna inventory. TFNA, court, longueur 170 mm Droite Dia. (mm) Angle du ...

Like the weather, the housing market usually cools in the

Inventory Control Form Variable Angle LCP Distal Radius Plates 2.4 mm VA LCP Dorsal Distal Radius Plate, Intermediate Column Shaft Holes Length (mm) Angled 02.115.630 3 41 +90° 02.115.631 3 41 –90° 02.115.640 4 49 +90° 02.115.641 4 49 –90° 2.4 mm VA LCP Dorsal Distal Radius L-Plate, 2 holes headThe RFN-ADVANCED™ System is a retrograde femoral nailing system designed to improve fixation for distal femur fractures 1. As part of the Advanced Nailing System, it is designed to address simple to complex trauma cases 2 with increased fixation and stability. 1,3. Product Specifications. How to Use This Product.SYNTHES (USA) SYNTHES (Canada) Ltd. To Order: (800) 523-0322 To Order: (800) 668-1119 Date: Hospital: Surgeon: Procedure: Implants Patient Information: J2210-I 10/12 Inventory Control Form 2.4 mm, 3.0 mm, 3.5 mm and 4.0 mm Cannulated Screws 2.4 mm Cannulated Screws Long Thread LENGTH LENGTH 211.810 10 mm 211.811 11 mm …Results: A total of 16 cases of TFNA implant breakage were recorded and analyzed. The predominant OTA/AO fracture classification was 31A3 (12 cases, 75%). The reduction quality was good in 10 cases, acceptable in 4 cases, and poor in 2 cases. The mean time to failure (and standard deviation) was 5.0 ± 2.2 months (range, 2.2 to 9.8 months).Screw-in-screw for improved fixation in osteoporotic bone. Unique and innovative screw-in-screw technology permits specific treatment of proximal humeral fractures. 3.5 mm locking screws inserted through the heads of MultiLoc screws target the postero-medial region with strong bone mineral density (BMD)1,2, reducing instances of varus collapse ...SYNTHES (USA) SYNTHES (Canada) Ltd. To Order: (800) 523-0322 To Order: (800) 668-1119 Date: Hospital: Surgeon: Procedure: Implants Patient Information: J2850-J 9/12 Inventory Control Form Orthopaedic Cable System Cables with Crimp Stainless Steel Cerclage ButtonsSynthes Tfna Inventory 20112024 Form Fill Out and Sign Printable PDF. Modular hand system implants and. Easily fill away pdf plain, edit, and sign them. Web inventory control form lcp vibrant helical hip system (dhhs) synthes (usa) synthes (canada) ag. Web synthes usa, llc 1101 synthes avenue monument, co 80132 manufactured or distributed by ...Femoral Neck System (FNS) Surgical Technique DePuy Synthes 3 AO Principles In 1958, the AO formulated four basic principles, which 1 4 2 3 4_Priciples_03.pdf 1 05.07.12 12:08 4 DePuy Synthes Expert Lateral Femoral Nail Surgical Technique AO PRINCIPLES In 1958, the AO formulated four basic principles, whichThe Femoral Recon Nail System is an integrated nailing system designed to adapt to multiple surgical approaches. The FRN System provides the choice of Greater Trochanter (GT) and Piriformis Fossa (PF) entry points and anatomical nail designs to support surgical preferences and facilitate hospital standardization. Contact Us.In our relatively small sample of 8 patients treated forintramedullary nail breakdowns with revision of the TFNA implant, agreater than the 1-in-3 rate of re-rupture of the implant …Introduction The recently developed femoral neck system (FNS) for treatment of femoral neck fractures (FNF), comprises theoretical biomechanical advantages compared to other implants. The aim of this study was to validate the safety and to report outcomes of patients treated with the FNS. Method A retrospective multicentric analysis of patients treated by FNS with a minimum of three months of ...Synthes products supplied in a non-sterile condition must be cleaned and steam-sterilized prior to surgical use. Prior to cleaning, remove all original packag - ing. Prior to steam-sterilization, place the product in an approved wrap or contain - er. Follow the cleaning and sterilization instruction given by the Synthes brochurePage 63 Miss-A-Nail Locking (continued) Insert the second screw using the same technique. Insert the nail Proceed with standard nail insertion technique (pages 21–25). Insert the second screw Drill for shaft screw Insert the 3.2 mm calibrated Insert the 5.0 mm guide wire through the sleeve shaft screw and into the femoral head until it is ...The TFNA System is designed to advance the treatment of trochanteric fractures by providing surgical options that help to preserve bone in insertion area due to reduced critical width, improve anatomical fit 1 and increase implant strength. 2 It is designed to reduce the risk of cut-out, 3,4 distal cortical impingement 1 and nail breakage, 2 ...Use signNow to e-sign and send Synthes Tfna Inventory for collecting e-signatures. be ready to get more. Create this form in 5 minutes or less. Get Form. Video instructions and help with filling out and completing Synthes Tfna Inventory Form. Find a suitable template on the Internet. Read all the field labels carefully.SYNTHES (USA) SYNTHES (Canada) Ltd. To Order: (800) 523-0322 To Order: (800) 668-1119 Date: Hospital: Surgeon: Procedure: Implants Patient Information: J2210-I 10/12 Inventory Control Form 2.4 mm, 3.0 mm, 3.5 mm and 4.0 mm Cannulated Screws 2.4 mm Cannulated Screws Long Thread LENGTH LENGTH 211.810 10 mm 211.811 11 mm 211.812 12 mm 211.813 13 ...Synthes (USA) Synthes (Canada) Ltd. To Order: (800) 523-0322 To Order: (800) 668-1119 Date: Hospital: Surgeon: Procedure: Implants Patient Information: J8398B 7/09 Inventory Control Form 3.7 mm Cannulated Locking and Conical Screws 3.7 mm Cannulated Locking Screws 3.7 mm Cannulated Conical Screws 02.240.210 10 mm 02.240.212 12 mm 02.240.214 14 ...The EMAX™ 2 Plus System is the ultimate high-powered, lightweight 1,2, small bone cutting system. Designed for surgeon comfort, this lightweight 1,2 device gives surgeons the flexibility 1,3,7, power, and low noise they need for long, complex neurosurgery and spinal procedures. MIDAS REX MR7 High-Speed Drill System (Medtronic)Inventory Control Form. TFN-ADVANCED™. Proximal Femoral Nailing System. Implants. (continued)Instruments. Available non sterile and sterile packed. Add “S” to catalog number to order sterile product. Guide Wires Part # Description 357.399 3.2 mm Guide Wire, 400 mm 09.037.010 3.2 mm Guide Wire, 475 mm 03.045.018 3.2 mm Guide Wire with ...Edit synthes tfna inventory. Rearrange and rotate pages, insert new and alter existing texts, add new objects, and take advantage of other helpful tools. Click Done to apply changes and return to your Dashboard. Go to the Documents tab to access merging, splitting, locking, or unlocking functions.02.118.408 7 holes, right 02.118.409 7 holes, left. 2.7 mm Variable Angle LCP Distal Tibia T-Plates. 02.118.306 4 holes 02.118.307 6 holes. Available nonsterile or sterile-packed. Add "S" to catalog number to order sterile product. Inventory Control Form. 2.7 mm/3.5 mm Variable Angle LCP Ankle Trauma System.The TFNA is available as either a short nail (lengths 170mm, 200mm, 235mm) or a long nail (lengths 300-480mm) and can be used with either a screw or helical blade. The proximal end of the nail is 15.66mm and distally the nails are available in 9mm, 10mm, 11mm, 12mm and 14mm diameters.The Trochanteric Fixation Nail-Advanced (TFNA®, DePuy Synthes) is the most recent addition to the DePuy-Synthes nailing system and allows cemented augmentation. The TFN-ADVANCED nail used in the literature is fitted with a cervicocephalic blade, and none has studied TFNA fitted with a cervicocephalic screw . The aim of the study was to ...DePuy Synthes TFN-ADVANCED™ Proximal Femoral Nailing System (TFNA) • Page 3 of 5 Results Results of the testing are summarized below, and comparison of the TFNA System head element options are displayed in Figure 4. • While the lag screw and helical blade are comparable in a center-center placement, the helical blade providesFill synthes tfna inventory sheet : Try Risk Free. Rate free tfna inventory control form. 4.0. Satisfied. 57 Votes. For pdfFiller’s FAQs. Below is a list of the ...202 patients (73.2%) were treated with a short TFNA (170 mm, 200 mm and 235 mm), the remaining 74 patients (26.8%) with a long TFNA (260–480 mm). A blade was used in 264 patients (96.0%), a screw in 11 cases (4.0%). The most frequently used blade length was 95 mm. Similarly, the most used screws had a length of 95 mm or 100 mm.A-Z Ortho 917 Lone Oak Rd Eagan, MN 55121 [email protected] Call 800.524.5194 Proud to offer products made in the USA.Tfna Inventory. Get to fillable template and complete it online using the instructions provided. Generate professional documents through airSlate SignNow. ... Synthes Tfna Inventory 2011-2024 Form . Create a custom synthes tfna inventory 2011 this meets your industry's specifications. Get Build. Show info Hide details. Wie it factory ...DESCRIPTION. The Femoral Neck System (FNS) is a solution for femoral neck fractures where the growth plates have fused or cannot be crossed. Designed for improved angular stability 1 and rotational stability 2 with the intent to reduce reoperations related to fixation complications. Product Specifications. How to Use This Product.241.618, 241.619, 241.622... Our locking calcaneal plates are available in mini, short, long, and extra-long lengths, with both left and right designs available. They offer a fixed-angle construct and permit multiple fixation points to buttress small fragments. They accept standard 2.7 and 3.5 mm cortex screws and 3.5 mm locking screws.SE_793148 AC página 2/7 Instruções de utilização TFNA, 9 mm, longo Lado direito Lado esquerdo Comprimento (mm) Ângulo do colo femoral 04.037.916S 04.037.917S 260 125°Our DePuy Synthes Hammertoe Continuous Compression Implants provide fixation for hammertoe correction procedures. This system features all contents in one sterile packed kit: Pre-loaded Nitinol implant in Standard or Large size options. Insertion tool with easy-to-use slider tab. Drill Guide, pins, and k-wire. Get in Touch with a Sales Consultant.SE_793147 AC page 2 / 6 Instructions for Use Femoral Recon Nail, Greater Trochanter B 9 mm Right Left Length 04.033.958S 04.033.959S 280 04.033.960S 04.033.961S 300The Trochanteric Fixation Nail-Advanced (TFNA®, DePuy Synthes) is the most recent addition to the DePuy-Synthes nailing system and allows cemented augmentation. The TFN-ADVANCED nail used in the literature is fitted with a cervicocephalic blade, and none has studied TFNA fitted with a cervicocephalic screw . …Find the right sample of Synthes tfna inventory control form and fill it out quickly without switching between your browser tabs. Discover more instruments to customize your Synthes tfna inventory control form form in the modifying mode. While on the Synthes tfna inventory control form page, just click the Get form buttonThe TFNA was associated with a higher risk of revision for nonunion than the TFN (HR, 1.86 [95% CI, 1.11 to 3.12]; p = 0.018). At the 3-year follow-up, implant breakage was 0.06% for the TFN and 0.2% for the TFNA; with regard to aperture failures related to the index fracture, there were 1 failure for the TFN group and 3 failures for the TFNA ...60.037.011 TFNA COMPLETE SET GRAPHIC CASE LABEL SHEET 1 Move To; Top of this tray ... The custom kit capabilities sole purpose is for convenience of inventory and ...TFNA, kurz, Länge 200 mm Rechts Durchmesser (mm) Femurhalswinkel 04.037.913S 9 125° 04.037.943S 9 130° 04.037.973S 9 135° 04.037.013S 10 125° 04.037.043S 10 130° 04.037.073S 10 135° 04.037.113S 11 125° 04.037.143S 11 130° 04.037.173S 11 135° 04.037.213S 12 125° 04.037.243S 12 130° 04.037.273S 12 135° TFNA, kurz, Länge 235 …Synthes Tfna Inventory 7434-9176 Form Apply a synthes tfna inventory 8664 template to doing choose download workflow more streamlined. Get Form. Show details Hide details How information works. Open form follow the ...LAS VEGAS, March 24, 2015 /PRNewswire/ -- DePuy Synthes Companies of Johnson & Johnson has launched the TFN-ADVANCED ™ Proximal Femoral Nailing System (TFNA), a nail, blade and screw system ...Tfna Inventory. Get your fillable template and complete it online using the instructions provided. Create proficient documents include signNow. ... Synthes Tfna Inventory 2011-2023 Form . Creating a custom synthes tfna inventory 2011 that meets your industry's functional. Get Form. Show details Disguise details. How it works ...The MAXFRAME™ System is a ring fixation system that can be customized by the surgeon to address the individual characteristics of each case and enables surgeons to construct circular frames for acute correction as well as gradual correction with computer assistance. 1,2 *. Product Specifications.Insert a locking bolt of the measured length with the hexag-onal screwdriver through the protection sleeve until the locking bolt head lies against the near cortex. The tip of the locking bolt should not project more than 1-2 mm beyond the far cortex. Remove the screwdriver and the protection sleeve. Distal Locking.In our relatively small sample of 8 patients treated forintramedullary nail breakdowns with revision of the TFNA implant, agreater than the 1-in-3 rate of re-rupture of the implant was served. Other variants of implants may be appropriate in revisionsetting, including other nails or conversion to arthroplasty.TFNA – Proximal Femoral Nailing System Surgical Technique DePuy Synthes 5 Indications and Contraindications TFNA short (Lengths 170 mm, 200 mm, 235 mm) Indications • Pertrochanteric fractures (31-A1 and 31-A2) • Intertrochanteric fractures (31-A3) • 235 mm nails are additionally indicated for high subtrochanteric fractures ContraindicationsDEPUY SYNTHES IS WITH YOU—AND YOUR PATIENTS EVERY STEP OF THE WAY Reference: 1. Walsh et al. Plasma-sprayed titanium coating to polyetheretherketone improves the bone-implant interface. The Spine Journal;2015: 1041-1049 2. Kurtz et al. PEEK biomaterials in trauma, orthopedic, and spinal implants. Biomaterials;28 (2007) …Synthes products supplied in a non-sterile condition must be cleaned and steam-sterilized prior to surgical use. Prior to cleaning, remove all original packag - ing. Prior to steam-sterilization, place the product in an approved wrap or contain - er. Follow the cleaning and sterilization instruction given by the Synthes "Import-ant ...In our relatively small sample of 8 patients treated forintramedullary nail breakdowns with revision of the TFNA implant, agreater than the 1-in-3 rate of re-rupture of the implant was served. Other variants of implants may be appropriate in revisionsetting, including other nails or conversion to arthroplasty.DIAMETER LENGTH. 03.113.024 2.8 mm 250 mm, 95 mm calibration. 3.5 mm Variable Angle Locking Screws, Self-Tapping, T15 Stardrive. LENGTH LENGTH.Inventory Control Form LCP Dynamic Helical Hip System (DHHS) SYNTHES (USA) SYNTHES (Canada) Ltd. To Order: (800) 523-0322 To Order: (800) 668-1119 Date: Hospital: Surgeon: Procedure: Implants Patient Information: J5047-E 2/11 LCP DHHS Compression Screw 211.890 4.5 mm Cortex Screws, self-tapping LENGTH 214.828 28 mm 214.830 30 mm 214.832 32 mm ...Introduction The aim of this study was to evaluate the clinical and radiological outcomes of patients treated with the TFN-Advanced™ Proximal Femoral Nailing system (TFNA¸ DePuy Synthes, West Chester, PA) including intra- and postoperative complications. Materials and methods All patients with an acute proximal femur fracture …Background: The TFNA (Trochanteric Fixation Nail Advanced) Proximal Femoral Nailing System (DePuy Synthes) is frequently used for intramedullary fixation of proximal femoral fractures.The TFN-ADVANCED (TFNA) Proximal Femoral Nailing System (DePuy Synthes) is a cephalomedullary nail intended for the treatment of proximal femoral fractures. Although nail breakages are infrequent, a recent implant retrieval study of 16 broken TFNA nails in Western Australia reported that the TFNA presented with a unique fracture …Our DePuy Synthes Hammertoe Continuous Compression Implants provide fixation for hammertoe correction procedures. This system features all contents in one sterile packed kit: Pre-loaded Nitinol implant in Standard or Large size options. Insertion tool with easy-to-use slider tab. Drill Guide, pins, and k-wire. Get in Touch with a Sales Consultant.02.226.010, 02.226.011, 02.226.012... View More. PRODUCT CODES. DESCRIPTION. DePuy Synthes Headless Compression screws are available in a range of sizes from 1-5-6.5 mm. They are self-drilling and self-tapping, allowing surgeons to control compression during fixation procedures. Get in Touch with a Sales Consultant.SYNTHES (USA) SYNTHES (Canada) Ltd. To Order: (800) 523-0322 To Order: (800) 668-1119 Date: Hospital: Surgeon: Procedure: Implants Patient Information: J2210-I 10/12 Inventory Control Form 2.4 mm, 3.0 mm, 3.5 mm and 4.0 mm Cannulated Screws 2.4 mm Cannulated Screws Long Thread LENGTH LENGTH 211.810 10 mm 211.811 11 mm …Synthes manufactures cases and trays intended to prepare the site and aid in im-plantation of Synthes implants. The clinical benefits for the cases and trays are based upon the implant devices rather than the cases and trays. Specific clinical benefits for the implants can be found in the respective Synthes implant instruc-tions for use.2 DePuy Synthes Femoral Recon Nail System (FRN) Surgical Technique AO Principles In 1958, the AO formulated four basic principles, which have become the guidelines for internal fixation.1, 2 Anatomic reduction Fracture reduction and fixation to restore anatomical relationships. Early, active mobilization Early, active mobilization of theInventory management helps make a business more profitable by reducing the cost of goods sold and increasing the sales. It helps increase speed, accuracy, accountability and mobili...Depuy synthes is submitting this report pursuant to the provisions of 21 cfr, part 803.This report may be based on information which depuy synthes has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by fda, depuy synthes or its employees that the report constitutes an admission that the device, depuy synthes, or its ...The custom kit capabilities sole purpose is for convenience of inventory and device usage identification. Last Updated: November 2023 This information is intended for use by healthcare professionals in the United States only.- DePuy Synthes offers several different configurations of BME ELITE Implants. The implant model number designates its shape and dimensions. Example: EL-3020S4 has a 30mm bridge length and 20 mm leg length in a straight con - figuration with 4 legs. Important note for medical professionals and operating room staff: These instruc-The TFNA was associated with a higher risk of revision for nonunion than the TFN (HR, 1.86 [95% CI, 1.11 to 3.12]; p = 0.018). At the 3-year follow-up, implant breakage was 0.06% for the TFN and 0.2% for the TFNA; with regard to aperture failures related to the index fracture, there were 1 failure for the TFN group and 3 failures for the TFNA ...DePuy Synthes TFNA Augmentation System: Applicant: Synthes (USA) Products, LLC: 1301 Goshen Parkway: West Chester, PA 19380 Applicant Contact: Christopher J. Medberry: Correspondent: Synthes (USA) Products, LLC: 1301 Goshen Parkway: West Chester, PA 19380 Correspondent Contact ...Inventory Control Form. TN-ADVANCED™. Tibial Nail System. Implants. Start: Hospitalized: Surgeon: How: Case Information (eg, Case ID):. Prepare your docs in minutes utilizing to easy step-by-step guide: Find the Inventory Govern Form - Synthes you require. Open computer using the cloud-based editor and start altering.Nail Design. Cannulated nails (from diameter 8 mm to diameter 13 mm) for reamed or unreamed techniques, enabling nail insertion over guide wire. The 2.5 mm or 3.0 mm ball tipped guide wires may be removed through the nail and insertion handle assembly (no exchange tube required).DePuy Synthes TFNA Augmentation System: Applicant: Synthes (USA) Products, LLC: 1301 Goshen Parkway: West Chester, PA 19380 Applicant Contact: Christopher J. Medberry: Correspondent: Synthes (USA) Products, LLC: 1301 Goshen Parkway: West Chester, PA 19380 Correspondent Contact ...Canulación de todos los clavos para la introducción guiada en la técnica con fresado y sin fresado. Clavos con una gran variedad de diámetros, de 9 a 15 mm, y longitudes de 160 a 480 mm. Configuración versátil para el bloqueo para el bloqueo estático, dinámico, estándar y de hoja espiral. retrógrado.Tfna Inventory. Get your fillable template and complete it online using the instructions provided. Create proficient documents include signNow. ... Synthes Tfna Inventory 2011-2023 Form . Creating a custom synthes tfna inventory 2011 that meets your industry's functional. Get Form. Show details Disguise details. How it works ...Inventory Control Form FRN-ADVANCED™ - Piriformis Fossa Femoral Recon Nailing System Implants Date: Hospital: Surgeon: Procedure: Case Information (eg, Case ID): FRN-ADVANCED™ Femoral Recon Nail System, Piriformis Fossa, 9 mm distal diameter, sterile Right Part # Left Part # Length (mm) 04.033.928S 04.033.929S 280 04.033.930S 04.033.931S 300TFNA, corto, longitud 170 mm Derecha Diámetro (mm) Ángulo del cuello femoral 04.037.912S 9 125° 04.037.942S 9 130° 04.037.972S 9 135° 04.037.012S 10 125° 04.037.042S 10 130° 04.037.072S 10 135° 04.037.112S 11 125° 04.037.142S 11 130° 04.037.172S 11 135° 04.037.212S 12 125° 04.037.242S 12 130° 04.037.272S 12 135° TFNA, corto ...SYNTHES (USA) SYNTHES (Canada) Ltd. To Order: (800) 523-0322 To Order: (800) 668-1119 Date: Hospital: Surgeon: Procedure: Patient Information: Inventory Control Form Titanium Adolescent Lateral Entry Femoral Nails 9 mm Titanium Adolescent Lateral Entry Femoral Nails-EX, sterile 04.031.944S 240 mm, right 04.031.945S 240 mm, left 04.031.946S 260 ...Managing inventory can be a challenging task for businesses of all sizes. It requires careful planning, organization, and monitoring to ensure that you always have the right amount.... A total of 16 cases of TFNA implant breakage were recorded and analyzThe TFNA (Trochanteric Fixation Nail Advanced) Proximal Femoral Page 63 Miss-A-Nail Locking (continued) Insert the second screw using the same technique. Insert the nail Proceed with standard nail insertion technique (pages 21–25). Insert the second screw Drill for shaft screw Insert the 3.2 mm calibrated Insert the 5.0 mm guide wire through the sleeve shaft screw and into the femoral head until it is ... The MAXFRAME™ System is a ring fixation system that c Product Codes : 03.010.127, 03.010.048, 04.003.240S... View More. PRODUCT CODES. DESCRIPTION. The EXPERT™ Cannulated Lateral Entry Femoral Recon Nail is designed to facilitate a lateral trochanteric entry site in the greater trochanter, providing ease of access while reducing the chance of varus deformity. Product Specifications. If you sell products in the course of business, there co...

Continue Reading