Synthes rfna surgical technique. System. PHILOS ® System is an anatomical LCP plating ...

Product Codes: 02.118.002, 02.118.002S, 02.118.003... View More

About This Product. The FRN-ADVANCED System is intended for treatment of fractures in adults and adolescents in which the growth plates have fused. Intended applications include: Subtrochanteric fractures. Ipsilateral neck/shaft fractures. Femoral shaft fractures. Impending pathologic fractures. Malunions and nonunions.At the end of this video, you should be able to describe the surgical technique for opening the distal femur using the RFNA Femoral Nailing System. This content is intended for Health Care Professionals in the United States.The EMPHASYS™ Stem includes design enhancements that can meet the needs for better patient outcomes and an efficient surgical workflow, including: Simplicity of Biomechanical Restoration. Insertion/Extraction Feature. Enhanced Collar Profile. 130˚ Neck Angle. ML Profile Reduction and Length Optimization. Get in Touch with a Sales Consultant.TFN - Titanium Trochanteric Fixation Nail System Surgical Technique DePuy Synthes. 7. Indications. The Synthes Titanium Trochanteric Fixation Nail (TFN) is intended to treat stable and unstable pertrochanteric fractures, intertrochanteric fractures, basal neck fractures, and combinations thereof.Page 77 Socket, hexagonal, 11.0 mm, length 180 mm 357.415 Shaft, hexagonal 5.0 mm, length 210 mm 357.920 Aiming Jig for “Miss-A-Nail” Technique for TFN 360.253 Locking Device for Holding Sleeve No. 314.110 TFN – Titanium Trochanteric Fixation Nail System Technique Guide Synthes...SURGICAL TECHNIQUE Preoperative planning makes it possible to: 1. Identify the lower level of the extended trochanteric osteotomy (ETO) required to fully remove the failed primary implant and any cement; this involves taking measurements in relation to several reference points (the top of the greater trochanter and the lesser trochanter, the femoral condyle, and any osteosynthesis material ...Variable Angle LCP™ Elbow System. Product Codes: 02.107.002, 02.107.002S, 02.107.102... View More. PRODUCT CODES. DESCRIPTION. The Variable Angle LCP™ Elbow System utilizes the variable angle locking technology platform that is based on a common approach to implant design and instrumentation, reducing complexity and ensuring a familiar ...4 DePuy Synthes Surgical Technique IMF Screw Set The following surgical technique assumes that the first screw is placed in the maxilla. However, screw place-ment, number of screws, and order of insertion are de-pendent on the fracture type, location and the surgeon’s preference. The screws must be positioned superior to the maxillary tooth …6 DePuy Synthes Variable Angle LCP Two-Column Volar Distal Radius Plate 2.4 Surgical Technique Postoperative, AP view Postoperative, lateral view, 20° inclined Postoperative, AP view Postoperative, lateral view Clinical Cases Case 1 24-year-old male with AO 23C2.1 fracture, fall from scaffold Preoperative, AP view Preoperative, lateral viewSurgical Technique LCS COMPLETE™ Knee System DePuy Synthes 1 Surgical Technique Surgical Summary 2 Incision and Exposure 4 Patella Resection 7 Tibial Jig Assembly 9 Lower Leg Alignment 10 Tibial Resection 12 Femoral Sizing 13 Intramedullary (I.M) Hole Preparation 14 Long Leg Alignment (Optional Simulated Distal Cut) 15The LCP Distal Femur Plate are designed with the following key components: Less Invasive Stabilization System (LISS) insertion guide for percutaneous placement of screws. Threaded holes in the plate head that accept cortex screws to create compression. Compatibility with self-tapping, self-drilling, cortex, and periprosthetic locking screws.Sep 23, 2021 · The Arthrex Femoral Nail System is targeted for use in intramedullary fixation of fractures of the femur. Consisting of antegrade and retrograde femoral opti...The DePuy Synthes VA-LCP PPFx Proximal Femur Plating System 3.5/4.5/5.0 provides two main plate options and an additional attachment plate for the treatment of periprosthetic hip fractures: VA-LCP PPFx Proximal Femur Plate 3.5/4.5/5.0. Designed with a focus on Type B fractures. Features an anatomically shaped plate head and shaft.synthes.vo.llnwd.netSimplified Surgical Process with reduced steps drive an efficient surgical flow and instrument innovation drives a simplified surgical process.1 Ability to trial directly off the distal reamer and modify version in situ. Simple Push/Pull connection feature. Option for non-retained and retained inserter for implantation and extraction.Synthes Rfna Technique Guide ... Surgical Technique DePuy Synthes 13 Opening the Femur 3. Insert guide wire Instruments 03.010.115 3.2 mm … Web ResultSE_793149 AA page 2 / 5 Instructions for Use Retrograde Femoral Nail Advanced Devices in scope Retrograde Femoral NailThe SIGMA™ HP Partial Knee is a high flex Fixed Bearing Unicompartmental Knee that is designed to provide solutions for any area of the knee depending on the degree of arthritis damage and includes femoral and tibia components. Get in Touch with a Sales Consultant.We would like to show you a description here but the site won’t allow us.Background. The standard approach to lateral tibial plateau fractures involves elevation of the iliotibial band (IT) and anterior tibialis origin in continuity from Gerdy's tubercle and metaphyseal flare. We describe an alternative approach to increase lateral plateau joint exposure and maintain iliotibial band insertion to Gerdy's tubercle.Ulnar shortening osteotomy is an established and frequently performed surgical procedure in wrist surgery. The technical aspects of the procedure have continued to develop in recent years, with instruments and implants being developed specifically for this purpose. Ulnar shortening osteotomy is required for different clinical indications and ...8 NCB ® Periprosthetic F Syst Surgical Technique The surgical technique is based on well-known standard plate osteosynthesis techniques, which give the surgeon tactile feedback regarding bone quality during drilling and tightening of the screws. In addition, with the use of locking caps the screws can be locked and made angularly stable.Web Result– One system for retrograde and antegrade technique – One system for left and right femur – Anatomic bend for ease in insertion and extraction – Cannulation of all nails … Web ResultTitanium Cannulated Lateral Entry Femoral Recon Nail Surgical Technique DePuy Synthes 13 Opening the Femur 3.Side Loading Spacers and Single-Use Instrument Kits Further Enhance Surgical Efficiency and Reduce Costs. WEST CHESTER, PA - October 21, 2020 - The Johnson & Johnson Medical Devices Companies* today announced that DePuy Synthes has launched its Radial Head Replacement System in the United States, further expanding its offering in extremities.The Radial Head Replacement System is used with ...Plantar fasciitis is a common condition of heel pain with a lifetime incidence up to 10%. For this entity, conservative treatment is considered the gold standard, involving non-steroidal anti-inflammatory drugs, stretching exercises of the plantar fascia, activity modifications, ice, and insoles. When patients do not respond to these treatments, partial or total plantar fascia release has been ...Please read these instructions for use, the Synthes brochure “Important Informa-tion” and the corresponding surgical techniques carefully before use. Ensure that you are familiar with the appropriate surgical technique. Material Material: Standard: PEEK (Polyetherether-ketone) ASTM F 2026 TAN (Ti-6Al-7Nb) ISO 5832-11 Intended useSurgical Technique Preparation and Insertion of Guide Wire 10 Screw Length Determination 11 Predrilling (Optional) 12 Countersink (Optional) 13 Screw Insertion 14 Screw Removal 15 4.5/5.5/6.5/7.5 Instruments 16 Product Information Implants 19 Instruments 28 Set Lists – Non-Sterile Implants 38 MRI Information 392 Surgical Technique • LCP Compact Hand Low profile plates and fully countersunk screws Anatomically contoured Rotation Correction Plate LCP combi-hole Facilitates intraoperative inspection of the reduction and correction of the rotational axis. Intraoperative choice wbet eenc omonsiesp r and locking holes. LCP Compact HandThis angular stability allows the stable fixation of an open-wedge osteotomy and hence its rapid osseous healing. Note: Plan the type and position of the osteotomy. The TomoFix medial high tibial plate is suitable for both open and closed-wedge osteotomies. This technique guide will explain the procedure of... Open the catalog to page 7.Screw Removal Set Surgical Technique DePuy Synthes 5 To remove cannulated screws The following table shows instruments that are required for the removal of broken cannulated screws. The instruments shown in parentheses are suitable if the break is in the shaft. Screw Removal Set. Instruments for removing DePuy Synthes screws. 309.510 309.520 ...Synthes guarantees the compatibil-ity of its different original implants and/or instruments. The product-specific instructions for use as described by Synthes must be followed. It is not advisable to mix Synthes products with those of different manufacturers, since designs, materials, mechanics, and construction are not harmonized.Please read these instructions for use, the Synthes brochure “Important Informa-tion” and the corresponding surgical techniques carefully before use. Ensure that you are familiar with the appropriate surgical technique. Material Material: Standard: TAN ISO 5832-11 TAV ISO 5832-3 CPTI ISO 5832-2 Intended useLayout 1. PFNA. Proximal Femoral Nail Antirotation. Technique Guide. Image intensifier control. Warning. This description alone does not provide sufficient background for direct use of the instrument set. Instruction by a surgeon experienced in handling these instruments is highly recommended. Reprocessing, Care and Maintenance of Synthes ...CORAIL Upgrade Kit Surgical Technique DePuy Synthes Joint Reconstruction 5 Surgical Technique Step 3: Femoral Canal Preparation Visualisation of the medullary canal axis The medullary canal axis is determined using the femoral canal explorer. Its entry point must be postero-lateral, near the trochanteric fossa. The canal explorer comprisesSE_793148 AC page 2 / 7 Mode d’emploi TFNA, 9 mm, long Droite Gauche Longueur (mm) Angle du col fémoral 04.037.916S 04.037.917S 260 125° 04.037.918S 04.037.919S 280 125°Product Codes: 02.118.002, 02.118.002S, 02.118.003... View More. PRODUCT CODES. DESCRIPTION. The 2.7 mm/3.5 mm VA LCP™ Ankle Trauma System is a comprehensive plating system that merges variable angle locking screw technology with conventional plating techniques for fixation of the ankle when growth plates have fused. Product Specifications.At the end of this video, you should be able to describe the surgical technique for opening the distal femur using the RFNA Femoral Nailing System. This content is intended for Health Care Professionals in the United States.6 DePuy Synthes ARCH™ Laminoplasty System Surgical Technique Laminoplasty 1. Surgical Approach The patient is positioned prone in head pins with the neck slightly flexed and posteriorly translated. The head of the bed should be raised to provide a level aspect to the surgical site. A standard midline approach should be used to exposeIf the reamed technique is used, the diameter of the largest medullary reamer applied must be 0.5 mm to 1.5 mm larger than the nail diameter. Always choose the largest diameter nail that fits into the intramedullary canal (B 9 mm nails should only be used for an intramedullary canal smaller than 11 mm). PFNA • Surgical Technique11🏥 This video guides you through the step-by-step procedure for treating distal femoral and femoral shaft fractures, ipsilateral femoral intercondylar fractu...Femoral Neck System (FNS) Surgical Technique DePuy Synthes 1 The Femoral Neck System (FNS) is a dedicated product for the fi xation of femoral neck fractures and offers the following features: System Highlights 3. DePuy Synthes Report: Static Cut Through Rotation Test in Bone Foam. 2017. Ref: 0000165855.* 4.11 DePuy Synthes Vet Surgical Technique 4.5 mm LCP® Distal Femur Plate Surgical Technique 4d With the skin retracted, make medial and lateral relief incisions in the extensor tendon approximately 1.5 cm abaxial to the sagittal incision - these will facilitate closure once the plate is in position.Locking screws serve to provide stability to comminuted, unstable me- taphyseal fractures or in osteopenic bone. The A.L.P.S. Fibula Plating System is intended for the fixa- tion of fractures, osteotomies and non-unions of the fibula, malleolus, distal tibia, metatarsals, scapula, clavicle, distal humerus and humeral head, olecranon, ulna ...RFN-Advanced System Surgical Technique DePuy Synthes 3 The RFN-Advanced Retrograde Femoral Nailing System (RFNA) is intended to stabilize fractures of the …Knotless Anchors. HEALIX ADVANCE™ Knotless Anchors were developed in collaboration with Thomas Knapp, M.D., Santa Monica, CA. 2. Versatility. Versatile Suture Configurations. Size & material. • Implants available in 4.75, 5.5, and 6.5 mm sizes. • Implants available in PEEK and BIOCRYL RAPIDE®. Biocomposite Material.Explore the role of a surgical technologist, their responsibilities, skills, training, and impact on patient care in the healthcare industry. Surgical technologists, often referred...Learn the Femoral shaft fracture: Fixation with Depuy-Synthes Expert retrograde/antegrade femoral nail (RAFN) surgical technique with step by select instructions on OrthOracle. Their e-learning platform contains high resolution images and adenine certified CME of the Femoral cheat fracture: Fixation at Depuy-Synthes Expert retrograde/antegrade ...Choose your Location. Last Updated Jun 1, 2023. From this site you can view or print Instructions For Use for DePuy Synthes devices. Manuals should be reviewed before using or implanting a device, or performing follow-up care.It should be noted that a distal femoral nail is inserted with a retrograde technique and in some literature the words are often used to mean the same thing. However, this shouldn't be confused with an antegrade nail (e.g. Lateral Femoral Nail - LFN) that is used to treat a distal third femoral fracture.4 Surgical Technique • LCP™ Superior Clavicle Plate The AO Principles of Fracture Management 1 Müller ME, Allgöwer M, Schneider R, Willenegger H. Manual of Internal Fixation. 3 rd ed. Berlin, Heidelberg New York: Springer 1991. 2 Buckley RE, Moran CG, Apivatthakakul T. AO Principles of Fracture Management: 3 rd ed. Vol. 1: Principles, Vol. 2: Specific fractures.10 Synthes Slipped Capital Femoral Epiphysis (SCFE) Screw System Technique Guide 3 Determine screw length Option A SCFE screw without washer The wire measurement is the measurement used to set the fixation sleeve (drill stop) on the drill. For example, if the measurement is 75 mm, set the fixation sleeve (drill stop) to 75 mm. Choose a 75 mm screw.synthes.vo.llnwd.net4 dePuy Synthes companies TFN–AdvANced Proximal Femoral Nailing System (TFNA) Surgical Technique ao PrIncIPleS 1 4 2 3 4_Priciples_03.pdf 1 05.07.12 12:08 4 DePuy …other than the recommended surgical technique. The surgeon should determine whether to remove the broken part based on the on associated risk. DePuy Synthes recommends that whenever possible and practical for the individual patient, the broken part should be removed • When implants are used to bridge gaps after chestIn our relatively small sample of 8 patients treated forintramedullary nail breakdowns with revision of the TFNA implant, agreater than the 1-in-3 rate of re-rupture of the implant was served. Other variants of implants may be appropriate in revisionsetting, including other nails or conversion to arthroplasty.Ramit Sethi is a New York Times best-selling author and creator of one of our favorite personal finance sites, I Will Teach You to Be Rich. In his weekly video Q&A for Lifehacker, ...24,00 x 15,20 x 2,20 cm. SKU. 1133553. Publicité. Publicité. Comparer. Réussir la note de synthèse, Gilbert Guislain, Studyrama Eds. Des milliers de livres avec la livraison chez vous en 1 jour ou en magasin avec -5% de réduction .RIA 2 (Reamer Irrigator Aspirator) Surgical Technique DePuy Synthes 3 Indications The DePuy Synthes RIA 2 System is intended for use in adults and adolescents (12-21 years) • To clear the medullary canal of the bone marrow and debris • To effectively size the medullary canal for the acceptance of an intramedullary implant or prosthesisIt was reported a study was conducted where a serious injury of non-union was noted.Study id: depuy - (b)(4).Subject id: (b)(4).Original injury was (b)(4).2023.Patient sustained a high trauma polytrauma.A retrograde femoral nail advanced was used to treat the grade iii shaft fracture on the left femur.Five (5) locking screws were used.Surgical date was (b)(4).2023.(b)(4).2023 union had not ...Raynham, Mass., Aug. 25, 2021-- The Johnson & Johnson Medical Devices Companies* announced that DePuy Synthes,** The Orthopaedics Company of Johnson & Johnson, will feature new products and technology solutions shaping new standards of care for modern day orthopaedics during the American Academy of Orthopaedic Surgeons (AAOS) annual meeting Aug. 31–Sept. 3 in San Diego.The TFNA System is designed to advance the treatment of trochanteric fractures by providing surgical options that help to preserve bone in insertion area due to reduced critical width, improve anatomical fit 1 and increase implant strength. 2 It is designed to reduce the risk of cut-out, 3,4 distal cortical impingement 1 and nail breakage, 2 ...If the extraction of the PFNA/PFNA-II blade is difficult, remove the locking bolt and the end cap and mobilize the nail to loosen the nail-blade connection. To detach the blade from the bone, use light hammer blows to slightly drive in the blade before removal of the blade. Patient Positioning. 1. Position patient.Entry Site and Surgical Approach Identify the entry site, which is in the piriformis fossa. The ideal entry point is adjacent to the greater trochanter at the lateral edge of the piriformis fossa. Initiate the entry site with a 3.2 mm guide pin through a stab incision proximal to the trochanteric region, in line with the femoral axis.Surgical Technique Product Information Slipped Capital Femoral Epiphysis (SCFE) 2 Screw System AO Principles 4 Indications 5 Clinical Case 6 Technique Tips 7 Implantation 8 Screw Removal 14 Implants 17 Instruments 18 Set Lists 20 Slipped Capital Femoral Epiphysis (SCFE) Screw System Technique Guide Synthes 1. Slipped Capital Femoral …Distal Femoral Nail Cleaning of instruments Cleaning of instruments Proper functioning of the instruments can be maintained by careful cleaning. Synthes... Page 27 DFN Distal Femoral Nail Surgical Technique Europe Czech Republic Hungary Slovakia Stratec Medical spol. s r. o. Stratec Medical Kft. Intes Poprad s.r.o. CZ-162 00 Praha 6 H-1021 ...This surgical technique guide alone does not provide suficient background for direct use of the ... DePuy Synthes StarDrive vs Hex Static Torsion Test. 2011. #SET_20110610. Screw Reference Chart Thread Diameter 2.7 mm 3.5 mm 4.0 mm Screw Type Cortex Locking Cancellous Drill Bit forThe Femoral Recon Nail System is an integrated nailing system designed to adapt to multiple surgical approaches. The FRN System provides the choice of Greater Trochanter (GT) and Piriformis Fossa (PF) entry points and anatomical nail designs to support surgical preferences and facilitate hospital standardization. Contact Us.Press down firmly until the tips engage the head of the screw. Page 22 To remove the instrument from the screw head, turn the palm handle counter-clockwise until the line on the side of the instrument is visible at the 30 line. Reduction travel: 30 mm DePuy Synthes MATRIX Spine System - Degenerative Surgical Technique...Please read these instructions for use, the Synthes brochure "Important Informa-tion" and the corresponding Surgical Techniques carefully before use. Ensure that you are familiar with the appropriate Surgical Technique. Material(s) Material(s): Standard(s): PEEK ASTM F 2026 TAN ISO 5832-11 Tantalum ISO 13782 Intended usePlease read these instructions for use, the Synthes "Important Information" and the corresponding surgical technique carefully before use. Ensure that you are fa-miliar with the appropriate surgical technique. Intramedullary Nailing Implants consist of metallic interlocking nails, interlockingThe TFN-ADVANCED Nailing System is a part of the Advanced Nailing System from DePuy Synthes and has features that allow surgeons to address proximal femur fractures. The system includes: Long Nails – Diameters: 9-12, & 14 mm. Lengths ranging from: 260 – 480 mm. Short Nails – Diameters: 9-12 mm.End Caps, for RFNA, Sterile Part # Extension (mm) 04.233.000S 0 mm 04.233.005S 5 mm 04.233.010S 10 mm. 3 ˜ Available nonsterile r sterile-packed. Add S t atalog number t rder sterile roduct. Inventory Control Form RFN-ADVANCED™ Retrograde Femoral Nailing System Some devices in this form may not have been licensed in accordance with …Our e-learning platform contains high resolution images and a certified CME of the Slipped upper femoral epiphysis : Percutaneous pinning with Synthes 73 mm cannulated screws surgical procedure. Slipped capital femoral epiphysis (SCFE, SUFE) has an incidence of between 5-10 per 100,000 children per year, generally occurring during the ...3 DePuy Synthes SUMMIT Tapered ip System Design Rationale and Surgical Technique FEMORAL NECK OSTEOTOMY Figure 4: Neck Osteotomy Align the neck resection guide with the long axis of the femur (Figure 4). The neck resection guide should be used to determine the level of the femoral neck resection in conjunction with pre-operative …Inventory Control Form - Stainless Steel. View PDF. Inventory Control Form - Titanium. View PDF. Select all documents (2) Download Selected Items. -. DePuy Synthes 3.5 mm Periarticular Proximal Humerus Plates are indicated for fractures, fracture dislocations, osteotomies, and nonunions of the proximal humerus, particularly in osteopenic bone.Cutting the nail to length. Prior to cutting the nails to length, verify the position of the nails in relation to the rotation of the leg. Once the nail is inserted to its final position, mark the nail with a pen or clamp at the planned cutoff point. (The cutoff point should be 10-20 mm outside of the cortex.)8 DePuy Synthes Surgical Technique MultiLoc Humeral Nailing System Case 1: 2-part surgical neck fracture 78-year-old woman. Simple fall. Treatment with: • MultiLoc Proximal Humeral Nail (short) B 8.0 mm • 3 MultiLoc screws • Distal locking Clinical Cases Preoperative, anteroposterior view Postoperative, anteroposterior viewSynthes USA, LLC 1101 Synthes Avenue Monument, CO 80132 To order (USA): 800-523-0322 To order (Canada): 844-243-4321 Synthes GmbH Luzernstrasse 21 4528 Zuchwil, Switzerland EU +800-88882020 EU +32 2 4037222 Note: For recognized manufacturer, refer to the product label. Please refer to the instructions for use for a complete list of indications,a device. Please read the instructions for use and the DePuy Synthes brochure "Important Information" carefully before use. Ensure that you are familiar with the appropriate surgical procedure. Materials Device(s) Material(s) Standard(s) VA-LCP PPFx Proximal Femur Plates and Proximal Femur Hook Plates 3.5/4.5/5.0 316L Stainless Steel ASTM F138About This Product. The Titanium Cannulated Adolescent Lateral Entry Femoral Nail is an expert nailing system with radiolucent instrumentation. It includes: End Caps. Easy-to-use instrumentation facilitates the surgical procedure. Standard Locking Screws. 5 mm Recon Screws. Get in Touch with a Sales Consultant.36 Surgical Technique • 2.7 mm Variable Angle LCP®Clavicle Hook Plate System. Product Information Implants. 2.7 mm Variable Angle Locking Screws*. 02.211.010– 2.7 mm Variable Angle Locking Screw 02.211.040 S elf-tapping, StarDrive recess, Stainless steel Available in 10 mm–40 mm lengths, in 2 mm increments 04.211.010– 2.7 mm Variable ...Synthes 5 Surgical Technique—DHS 2. P. Regazzoni, Th. Rüedi, R. Winquist, and M. Allgöwer. The Dynamic Hip Screw Implant System. Berlin: Springer-Verlag, 1985. 5. 38 mm barrel 25 mm barrel Plate selection Barrel length The standard 38 mm barrel length is most commonly indicated. The 25 mm short barrel is indicated for specific clinical situations, …Fixate plate to the bone. Use a 1.4 mm diameter drill bit to pre-drill and insert the 1.85 mm Matrix screws of the appropriate length to fixate the plate to the underlying bone. Note: A 1.5 mm diameter drill bit can be used in dense bone to facilitate screw insertion (4 mm-8 mm lengths). Cautions.Femoral Neck System (FNS) Surgical Technique DePuy Synthes 1 The Femoral Neck System (FNS) is a dedicated product for the fi xation of femoral neck fractures and offers the following features: System Highlights 3. DePuy Synthes Report: Static Cut Through Rotation Test in Bone Foam. 2017. Ref: 0000165855.* 4.The Femoral Recon Nail System is an integrated nailing system designed to adapt to multiple surgical approaches. The FRN System provides the choice of Greater Trochanter (GT) and Piriformis Fossa (PF) entry points and anatomical nail designs to support surgical preferences and facilitate hospital standardization. Contact Us.back of this surgical technique and the package insert is available on the website listed . Indications Metacarpophalangeal Joint Implant Arthroplasty Rheumatoid or post-traumatic disabilities with: • Fixed or Stiff MP Joints • X-Ray Evidence of Joint Destruction or Subluxation • Ulnar Drift, Noncorrectable By Surgery of Soft Tissues AloneSystem. PHILOS ® System is an anatomical LCP plating system for proximal humerus fracture fixation. It includes the PHILOS ® Percutaneous Aiming System, for a less invasive transdeltoid approach. Unfortunately, we can’t detect an electronic copy of the Instructions for Use (IFU) you are seeking. You can locate the IFU for this product by:4 Surgical Technique • LCP™ Superior Clavicle Plate The AO Principles of Fracture Management 1 Müller ME, Allgöwer M, Schneider R, Willenegger H. Manual of Internal Fixation. 3 rd ed. Berlin, Heidelberg New York: Springer 1991. 2 Buckley RE, Moran CG, Apivatthakakul T. AO Principles of Fracture Management: 3 rd ed. Vol. 1: Principles, Vol. 2: Specific fractures.Clinical Cases PFNA 94 years, female 31-A1.1 0 days post-op 14 weeks post-op 11 months post-op 93 years, female, 31-A3.3 4 days post-op 4 weeks post-op 5 months post-op 12 Synthes PFNA. With Augmentation Option. Technique Guide . …Please read these instructions for use, the Synthes brochure "Important Informa-tion" and the corresponding surgical techniques carefully before use. Ensure that you are familiar with the appropriate surgical technique. Material Material: Standard: TAN ISO 5832-11 PEEK ASTM F 2026 TAV ELI ASTM F 136 Intended use. Oct 4, 2016 · pull traction at 30° angle over triangle for reductionTechnique ®Guide ARCH Fixation System DePuy Synthes Com UFN Unreamed Femoral Nail/CFN Cannulated Femoral Nail Surgical Technique DePuy Synthes 1 Table of Contents Indications for femoral nailing 2 Indications for UFN/CFN 6 Implants 10 Preoperative planning 14 Instruments for opening the femur 15 Open the femur (all locking procedures) 16 Proximal locking Standard locking A 24 Spiral blade locking B 32 SE_793148 AC page 2 / 7 Instructions for Use TFNA, 9 mm, 2.7 mm Variable Angle Locking Calcaneal Plates Surgical Technique DePuy Synthes 3 AO Principles and Indications Indications The DePuy Synthes 2.7 mm and 3.5 mm Variable Angle LCP® Midfoot/Hindfoot System is indicated for fixation of osteotomies, fusions, fractures, nonunions, malunions, and replantations of small bones and small bone synthes.vo.llnwd.net...

Continue Reading