Synthes pelvic inventory. The Acumed Clavicle Hook Plating System includes four plate lengths ...

The DePuy Synthes Large External Fixation Systems are intended

This is an educational video demonstrating a technique for applying a pelvic external fixator to a patient with a open book pelvic fracture with haemodynamic...The Acumed Pelvic Plating System is a comprehensive set of plates, screws, and instrumentation designed for fractures, fusions, and osteotomies of the acetabulum, sacrum, ilium, and pelvic ring. The Pelvic Plating System can also be used for sacroiliac joint dislocations and pubic symphysis disruptions. The implants in the Pelvic Plating System ...of DePuy Synthes products. Instruction by a surgeon experienced in handling these products is highly recommended. Processing, Reprocessing, Care and Maintenance For general guidelines, function control and dismantling of multi-part instruments, as well as processing guidelines for implants, please contactMortality. Constantini et al J Trauma Acute Care Surg 2016. - multi-centred prospective study of 1339 patients with pelvic fractures at Level 1 trauma centers. - overall mortality 9%. - pelvic trauma with shock has 30% mortality. Dente et al Am J Surg 2005. - 44 open pelvic fractures. - overall mortality 45%. - concurrent intra-abdominal injury ...The DePuy Synthes Variable Angle Locking Hand System consists of plates that are anatomic, procedure-specific, and available in both stainless steel and titanium. The Variable Angle Locking Hand System offers instrumentation to aid in: • temporary fixation, correction or stabilization of the hand bones • plate adaptation • construct creation2 DePuy Synthes Spring Plates 3.5 Surgical Technique Description In­pelvic­and­acetabular­surgery,­it­is­often­difficult­to­reduce­ and­fix­small­bone­fragments.­The­Spring­Plates­3.5­are­in-tended­to­reduce­and­stabilize­bone­fragments­that­are­too­ small­for­screws.­They­can­be­used­individually­or­in­con-of DePuy Synthes products. Instruction by a surgeon experienced in handling these products is highly recommended. Processing, Reprocessing, Care and Maintenance For general guidelines, function control and dismantling of multi-part instruments, as well as processing guidelines for implants, please contactNow that summer is over, it's a good time to log into your airline and hotel accounts. Check to see how many points or miles you have, when they expire and check for any leftover c...The DePuy Synthes Cannulated Compression Headless Screws are indicated for use in bone reconstruction, osteotomy, arthrodesis, joint fusion, fracture repair, and fracture fixation of bones appropriate for the size of the device. Screws are intended for single use only. Contraindications The implant should not be used in a patient who hasFeatures & Benefits. LCP Combi-holes. Combi-holes in the shaft accept: 3.5 mm locking screws. 3.5 mm cortex screws. 4.0 mm cancellous bone screws. Multiple Screw Options. Five coaxial distal holes accept 2.4 mm and 2.7 mm locking and cortex screws to provide multiple screw options. Kirschner Holes.DESCRIPTION. The Femoral Neck System (FNS) is a solution for femoral neck fractures where the growth plates have fused or cannot be crossed. Designed for improved angular stability 1 and rotational stability 2 with the intent to reduce reoperations related to fixation complications. Product Specifications. How to Use This Product.02.108.300, 02.108.300S, 02.108.301... View More. PRODUCT CODES. DESCRIPTION. The Pediatric LCP ™ Plate System is designed for stable fixation of varus, valgus or rotational osteotomies and trauma applications in pediatric orthopaedics. The plates feature a universal design to fit both the left and right femurs. Product Specifications.The Universal Small Fragment System can support all 2.7 mm/3.5mm non-locking, LCP™ System, and VA LCP™ Locking Technologies. It consists of two components: A core set of instruments, screws, and standard implants. Modular anatomic implant trays for supported small fragment anatomy. Get in Touch with a Sales Consultant.Responsiveness of the Spanish Pelvic Floor Distress Inventory and Pelvic Floor Impact Questionnaires Short Forms (PFDI-20 and PFIQ-7) in women with pelvic floor disorders. Beatriz Sánchez Sánchez María Torres Lacomba Beatriz Navarro Brazález Ester Cerezo Téllez Soraya Pacheco da Costa C. OrtegaCreate a blueprint of the proximal femur on the ap pelvic x-ray, rotate this blueprint around the center of the femoral head until you have a satisfactory containment. Calculation of the correction: ... 12 Synthes LCP Pediatric Hip Plates 3.5 and 5.0 for valgus osteotomies Technique Guide 0X6.001.057_AA 08.02.11 13:21 Seite 12. 1 2 1The Titanium Cannulated Adolescent Lateral Entry Femoral Nail is an expert nailing system with radiolucent instrumentation. It includes: End Caps. Easy-to-use instrumentation facilitates the surgical procedure. Standard Locking Screws. 5 mm Recon Screws. Get in Touch with a Sales Consultant.Execute Synthes Low Profile Pelvic Inventory in just a couple of clicks by following the instructions listed below: Pick the document template you will need in the collection of legal forms. Choose the Get form button to open the document and begin editing. Submit the necessary fields (they are marked in yellow).3.5 mm. Remove the cortex screw from hole 1 and replace it with a bicortical, self-tapping locking screw. Screw the drill sleeve exactly into the threaded part of the combi-hole and drill the hole with the LCP drill bit 4.3 mm. Determine the screw length and insert the screw as described on page 15.A-Z Ortho 917 Lone Oak Rd Eagan, MN 55121 [email protected] Call 800.524.5194 Proud to offer products made in the USA.DEPUY SYNTHES IS WITH YOU—AND YOUR PATIENTS EVERY STEP OF THE WAY Reference: 1. Walsh et al. Plasma-sprayed titanium coating to polyetheretherketone improves the bone-implant interface. The Spine Journal;2015: 1041-1049 2. Kurtz et al. PEEK biomaterials in trauma, orthopedic, and spinal implants. Biomaterials;28 (2007) 4845-4869 3.Powered by a legacy of orthopaedic excellence, the DePuy Synthes Variable Angle LCP™ Periprosthetic Proximal Femur Plating System 3.5/4.5/5.0 aims to deliver the real strength and versatility needed by surgical teams that demand the best outcome for patients. 1. Get in Touch With a Consultant.Nail for Pelvic C-Clamp, cannulated, Stainless Steel Article No. Length (mm) 02.306.006 190 02.306.007 210 Steinmann Pin, Stainless Steel ... Synthes External Fixation and …Inventory Control Form 4.5 mm VA LCP™ Curved Condylar Plate System with OPTILINK™ Screw Technology Some devices in this form may not have been licensed in accordance with Canadian law and may not be for sale in Canada. Please contact your sales consultant for items approved for sale in Canada. Ti/VALCPCC/ICF/V2 04/22 Page 1 of 2Inventory Control Form 2.0 mm Quick Insertion Screw (QIS) and 2.0, 2.5, 3.0, 3.5, 4.0 mm Cannulated Compression Headless Screws (CCHS) Implants The screws are made of titanium alloy (TAV) 10 mm 12 mm 14 mm 16 mm 18 mm 20 mm 22 mm 24 mm 26 mm 28 mm 30 mm 32 mm 34 mm 36 mm 38 mm 40 mm 20 mm 22 mm 24 mm 26 mm 28 mm 30 mm 32 mm 34 mm 36 mm 38 mm 40 ...Additional Info. Unit of Measurement: Each. Catalog Number: 105.04. Includes an array of cannulated stainless steel screws (full thread and partial thread), instrumentation, and storage. Multiple 4.5 mm cannulated screw assortments available. CLICK HERE for list of 214.720-214.772 / 214.520-214.572 screw assortment and components.The 3.5/4.5 mm Variable Angle LCP™ Periprosthetic Proximal Femur Plating System consists of plating solutions for periprosthetic fractures around a hip prosthesis. It aims to deliver the real strength and versatility needed by surgical teams that demand the best outcome for patients. 1. Product Specifications.DESCRIPTION. The Collinear Reduction Clamp features a sliding mechanism that accepts different attachment arms to create a versatile reduction tool that adapts to your clinical needs. The arms can be mounted in four positions to accommodate long bone, articular, and pelvic fractures. Get in Touch with a Sales Consultant.Synthes (USA) Synthes (Canada) Ltd. To Order: (800) 523-0322 To Order: (800) 668-1119 Date: Hospital: Surgeon: Procedure: Implants Patient Information: J2933-M 12/12 Inventory Control Form 4.5 mm, 6.5 mm, 7.0 mm and 7.3 mm Cannulated Screws 4.5 mm Cannulated Screws, partially threaded LENGTH LENGTH 214.520 20 mm 214.522 22 mm 214.524 24 mm 214. ...Inventory Control Form TomoFix® osteotomy System Patient Information: 5.0 mm Titanium Locking Head Screws, self-tapping lenGtH 413.324 24 mm 413.326 26 mm 413.328 28 mm 413.330 30 mm 413.332 32 mm 413.334 34 mm 413.336 36 mm 413.338 38 mm 413.340 40 mm 413.342 42 mm 413.344 44 mm lenGtH 413.346 46 mm 413.348 48 mm 413.350 50 mm 413.355 55 mmThe Synthes Large External Fixation System is intended to provide treatment for long bone and pelvic fractures that require external fixation. Specifically, the components can be used for: – Stabilization of soft tissues and fractures – Polytrauma/multiple orthopaedic trauma – Vertically stable pelvic fractures, or as a treatment adjunctLow Profile 3.5mm Pelvic System. The 3.5mm Low Profile Pelvic implants are intended for temporary fixation, correction or stabilization of bones in the pelvis. 1. Get in Touch with a Sales Consultant.DESCRIPTION. Our LCP™ Curved Locking Compression Plates are part of the DePuy Synthes Trauma LCP™ Locking Compression Plate System. This stainless steel and titanium plate screw system merges locking screw technology with conventional plating techniques for use in various orthopaedic trauma applications. Get in Touch with a Sales Consultant.Low Profile 3.5mm Pelvic System. The 3.5mm Low Profile Pelvic implants are intended for temporary fixation, correction or stabilization of bones in the pelvis. 1. Get in Touch with a Sales Consultant.The DePuy Synthes Cannulated Compression Headless Screws are indicated for use in bone reconstruction, osteotomy, arthrodesis, joint fusion, fracture repair, and fracture fixation of bones appropriate for the size of the device. Screws are intended for single use only. Contraindications The implant should not be used in a patient who hasThe Acumed Pelvic Plating System is a comprehensive set of plates, screws, and instrumentation designed for fractures, fusions, and osteotomies of the acetabulum, sacrum, ilium, and pelvic ring. The Pelvic Plating System can also be used for sacroiliac joint dislocations and pubic symphysis disruptions. The implants in the Pelvic Plating System ...Follow our simple steps to get your Synthes Large Frag Inventory ready quickly: Select the template from the library. Type all required information in the required fillable fields. The easy-to-use drag&drop interface makes it easy to add or move fields. Ensure everything is filled in properly, with no typos or lacking blocks.Synthes (USA) Synthes (Canada) Ltd. To Order: (800) 523-0322 To Order: (800) 668-1119 Date: Hospital: Surgeon: Procedure: Implants Patient Information: J8398B 7/09 Inventory Control Form 3.7 mm Cannulated Locking and Conical Screws 3.7 mm Cannulated Locking Screws 3.7 mm Cannulated Conical Screws 02.240.210 10 mm 02.240.212 12 mm …Additional Info. Unit of Measurement: Each. Catalog Number: 105.04. Includes an array of cannulated stainless steel screws (full thread and partial thread), instrumentation, and storage. Multiple 4.5 mm cannulated screw assortments available. CLICK HERE for list of 214.720-214.772 / 214.520-214.572 screw assortment and components.The pelvic C-clamp is a tool designed to provide emergency stabilization to patients suffering from c-type pelvic ring injuries. We describe a case in which a patient's open book pelvic ring injury with a zone three sacral fracture is reduced intraoperatively with the use of a pelvic C-clamp and stabilized with transsacral screws. Go to: 1.Large External Fixation System. The Large External Fixation System uses a modular construction to allow flexibility and a variety of forms of assembly to externally stabilize long bones, pelvic ring fractures, arthrodesis, and osteotomies. The system combines the Modular Knee Bridge and the Pelvic Frame. Product Specifications.What makes the synthes deep profile digenetic catalog legally validate? As the business ditches in-office working conditions, the completion of documents increase occurs back. The synthes pelvic implant set inventory control vordruck isn’t an exception. Deal with it using digital accessories is different from doing so in the physical world.Pelvic. To meet the challenge of treating patients with traumatic injuries, Zimmer Biomet offers a wide range of fracture fixation products specifically designed to address the intricate anatomy and physiology of the extremities.2 DePuy Synthes Large Distractor–Femur Surgical Technique Standard Femoral Distraction An alternative to the fracture table In the treatment of multitrauma patients, it is frequently ... is particularly advantageous in treating pelvic and joint fractures where large forces are present. For pelvic fractures: – An anterior approach can be utilized, which requires a …Inventory Control Form LCP Clavicle Plate System Synthes (USA) Synthes (Canada) Ltd. To Order: (800) 523-0322 To Order: (800) 668-1119 Date: Hospital: Surgeon: Procedure: Implants Patient Information: J9001-D 10/10 3.5 mm LCP Superior Anterior Clavicle Plates, with Lateral Extension 3.5 mm LCP Superior Anterior Clavicle Plates HOLES HOLESPelvic ring fractures often occur as part of a trauma comprising high energy impact. They still show an approximately 10% overall mortality [], mainly caused by exsanguination.The presacral venous plexus and the fracture surface are most likely the main source of bleeding [] and patients suffering from an unstable pelvic ring fracture have, according to the Tile classification type B and C ...Patient information: DePuy Synthes (USA) To order: (800) 227-6633 DePuy Synthes (Canada), Ltd. To order: (800) 668-1119 InvenTory ConTrol Form Titanium MatrixNEUROTM implants Titanium MatrixNEUROTM Screws Self-Drilling PaCkage oF 20 04.503.103.20 3 mm 04.503.104.20 4 mm 04.503.105.20 5 mm PaCkage oF 1 04.503.103.01 3 mm 04.503.104.01 4 mmSynthes (USA) Synthes (Canada) Ltd. To Order: (800) 523-0322 To Order: (800) 668-1119 Date: Hospital: Surgeon: Procedure: Implants Patient Information: J4963-E 9/12 Inventory Control Form Modular Hand System Implants and Instruments (Stainless Steel) 200.531 11 mm 200.532 12 mm 200.533 13 mm 200.534 14 mm 200.526 6 mm 200.527 7 mm 200.528 8 mm ...Learn more on the 1.5 mm LCP® Modular Mini Fragment System by DePuy Synthes, with a variety of plate styles to address a range of small bone fractures.The Synthes Large External Fixation System is intended to provide treatment for long bone and pelvic fractures that require external fixation. Specifically, the components can be used for: – Stabilization of soft tissues and fractures – Polytrauma/multiple orthopaedic trauma – Vertically stable pelvic fractures, or as a treatment adjunctSynthes Large External Fixation is intended for use to provide treatment for long bone and pelvic fractures that require external fixation. Code Information: Part Number 390.007, Lot Number 6800599 ... The firm is requesting that you please examine your inventory for products with the above Part and Lot number and remove them. Call Synthes at 1 ...Synthes (USA) Synthes (Canada) Ltd. To Order: (800) 523-0322 To Order: (800) 668-1119 Date: Hospital: Surgeon: Procedure: Large External Fixator Patient Information: J2906-L 3/13 390.002 Large Multi-Pin Clamp, 6 position 390.003 Rod Attachment for Large Multi-Pin Clamp 390.004 Large Multi-Pin Clamp, 4 position 390.005 Large Combination ClampPowered by a legacy of orthopaedic excellence, the DePuy Synthes Variable Angle LCP™ Periprosthetic Proximal Femur Plating System 3.5/4.5/5.0 aims to deliver the real strength and versatility needed by surgical teams that demand the best outcome for patients. 1. Get in Touch With a Consultant.The modular set for pelvic implants. The design of the plates has been modified to allow easier contouring to the patients anatomy, together with optimized screw hole geometry for a wider range of angulations. The completely redesigned pelvic C-clamp comes in a set for emergency pelvic stabilization ready to use out of the box. A new Modular ...Inventory Control Form Some devices in this form may not have been licensed in accordance with Canadian law and may not be for sale in Canada Please contact your sales consultant for items approved for sale in Canada. *2.4 mm Cortex Screws in lengths 42–60 mm are available in the 2.4/2.7 mm VA-LCP Forefoot/Midfoot Plating System.In addition to the extra long 3.5mm and 4.5mm self-tapping cortical screw range, the Matta Pelvic Set includes. a selected range of partially threaded 6.5mm cancellous screws. These can offer the option to perform a strong independent interfragmentary Lag-Screws fixation without the need for an additional screw set.In today’s fast-paced business environment, effective inventory management is crucial for maintaining a smooth workflow and maximizing profitability. One key tool that can streamli...A-Z Ortho 917 Lone Oak Rd Eagan, MN 55121 [email protected] Call 800.524.5194 Proud to offer products made in the USA.A number of high-profile firms and startups have set up logistics networks in India in the last decade as they attempt to digitize neighborhood stores. Bangalore-headquartered star...Inventory Control Form 3.5 mm Low Profile Pelvic System Some devices in this form may not have been licensed in accordance with Canadian law and may not be for sale in Canada. Please contact your sales consultant for items approved for sale in Canada. Drill Bits, quick couplingAbout This Product. The LCP™ Proximal Tibia Plates are indicated for fractures of the proximal tibia and treatment of nonunions, malunions, and osteopenic bone. They are available in the following options: 3.5 mm LCP Proximal Tibia Plate. 3.5 mm LCP Proximal Tibia Plate – Low Bend. 4.5 mm LCP Proximal Tibia Plate.. In today’s fast-paced business environment, effectiWe have 1 Synthes Pelvic C-Clamp II manual av Now that summer is over, it's a good time to log into your airline and hotel accounts. Check to see how many points or miles you have, when they expire and check for any leftover c...Cleaning & Sterilization Guidelines. Cleaning & Sterilization Guidelines for Synthes Trauma, CMF, Biomaterials and Spine Devices. Synthes reusable devices, instrument trays and ca of DePuy Synthes products. Instruction by a surgeon experienced in handling these products is highly recommended. Processing, Reprocessing, Care and Maintenance For general guidelines, function control and dismantling of multi-part instruments, as well as processing guidelines for implants, please contact Synthes (USA) Synthes (Canada) Ltd. To Order: (800) 523-0322 To Order...

Continue Reading