Alltrax controller fault codes. THROTTLE AND BRAKE CODES 31 ALARM CODES 32 CODE DEFINITIONS 33 WARRA...

From there, page 28: "1 Green and 6 Red LED Fl

Looked at controller (sr48500) and it’s giving the blink code for pre-charge failure. Unsure what to check. Everything is new (less than a month) and has been working great.Alltrax says pre- charge failure occurs when B+ voltage is 6v or more below key switch voltage at ksi input on controller. I will look again this evening but I did notice a 1v drop across the solenoid when closed. Seem like a lot of resistance through a closed contact. And the connections are pretty tight. That would account for 1 of the 6 volts.If an attacker manages to access your D-Link router’s login screen, and your router is old enough, it’s possible that they can take control of the router, inject it with code, and...1111 Cheney Creek Rd Grants Pass, OR. 97527 Phone: 5414763565 Fax: 5414763566. Doc100013C_OPNPXMiniMan.pub, 1212010. A n E n g i n e e r e d S o l u t i o n.If you are involved in an accident deemed to be your fault, the full coverage portion of your auto insurance policy should pay to repair your vehicle. If the accident is deemed to ...2006: NCX – Alltrax Controller: STOCK Replacement for Shunt; Motors; 36-48VDC; 300-400Amp (Peak) Stock Fleet Grade; Non-Programmable; Solenoids, 200 & 400amp high performance rated; 24V, 36V, 48V, and 72VDC; SOL-200 with 800Amp Break; SOL-400 with 1000Amp Break; Use with Alltrax 500amp and higher controllers;I watched the status light on the controller while depressing the throttle, and after I get the first green light indicating a 0-5K throttle, I get 2 green lights and 6 red lights; the controller instructions says that indicates "Low Throttle under range".EZ-GO Performance Shunt Motor Controllers. EZ-GO DCS/FAIRPLAY. Select options. XCT48300DCS 36 or 48 Volt 300 Amp $ 747.00 - $ 778.00; Select options. XCT48400DCS 36 or 48 Volt 400 Amp $ 834.00 - $ 865.00; ... Alltrax Inc PO Box 510 Murphy, OR 97533 Phone: 541-476-3565 Send requests and comments to: [email protected] Subscribe to Our Mailing ...Re: Alltrax SR48500 low throttle input underrange. Quote: Originally Posted by JohnnieB. Across J4 and J5 with the white and black wires attached ought to be 10V when solenoid clicks and 6V with pedal on floor, so both of the readings you got were way out of range on the low voltage side. Disconnect the white and black wires from J4 and J5 and ...Largest Selection of High Speed Yamaha Golf Cart Controllers in the World - G2 G19 G22 G29 Drive - 300 400 500 AMP - Guaranteed lowest part prices - 36 & 48 volt - upgrade your Electric Golf Cart with a High Speed & Torque Alltrax ControllerI had that happen a couple weeks ago. Made no sense. I cut it off, went back 10 mins later and blink codes for "Pre-Charge Failure". This is odd as the XCT its pre-charge controlled thru the Run/Tow switch. I cycled it a few times and still nothing. I powered everything down and still nothing. I verified current thru the Run/Tow and to the ...Re: Alltrax fault code 5 The controller is capable to push the motor to higher RPM's and if the bearing was bad, then this could be the cause of all that. When putting this controllers on 4+ fleet carts, always replace motor bearing and check brushes and replace if the are under 50% of their life.Alltrax Bad Boy Buggie 4WD Controller Kit. Introducing an advanced motor controller designed for today's demanding markets, featuring a thermal plastic enclosure made of ABS, 48-volt controllers, 500-amp controllers, a wire harness adaptor compatible with XT, XTO, XT Classic, BB2, and AMS4, flexible USB programming, solenoid control output for "Main DC Contactor Control," a mount included for ...200-300 AMP CONTROLLER. 200-300 Amp controller would be the perfect one if you intend to use or using a Club Car for normal trips in your neighborhood or normal golf course trips. This controller is best suited for two passenger Club Cars. Salient features of this 200-300 Amp controller are as follows: This controller can easily be paired with ...The beep is gone with the old curtis controller. So is the battery light. Best to get a digital voltmeter display so you can keep an eye on battery voltage and learn when you've reached the cut-off point minimum 50% SOC. Dunno about the low speed, but get the Alltrax Toolkit software and connect a laptop and see if there are any fault codes.Now both controllers are giving fault codes that indicate the controller is bad. 06-21-2017, 09:47 AM #3: mjroman20. Gone Wild . Join Date: Apr 2015. Location: Pennsylvania. Posts: 378 Re: bad boy buggy sevcon controller swap ... Alltrax is finalizing a conversion from Sevco controller to Alltrax controller they have the 4wd …Just saw this from an older post from ScottyB… The new XCT and SR controls from Alltrax do not use an external pre-charge resistor... they have the pre-charge feature built into them.Alarm motorcycle cheap circuit system touch schematic simple gr next circuitdiagram Full yamaha fault code list to help with troubleshooting your Motorcycle alarm system wiring diagram Wirin ... Alarm motorcycle cheap circuit system touch schematic simple gr next circuitdiagram Alltrax controller throttle wire ebike razor contactor Yqs for ...This fault will automatically clear and the charger will restart charging when this problem is removed. Check the battery and connections to the battery. Check the nominal battery voltage. The first two digits of the four digit model name indicate the battery voltage the charger supports.LED Blink Codes: At power up, # of green blinks indicates configured throttle type: 1 Green = 0-5k 4 Green = EZ-GO inductive (ITS) 7 Green = CLUBCAR 5K-3-wire Normal display status: Solid Green: Controller ready to run Solid Red: Controller in programming modeThe throttle code blinks on controller power up and alarm codes blink when the alarm happens. All alarms are self clearing so when the alarm event is over, the controller resumes normal operation, except for the Short Circuit alarm that needs a power off cycle to clear the alarm. throttle codes: 1 Green LED Flash = 0-5k throttleRepaired Controller + 1st eGator = 3,1 fault code. Running Controller + 1st eGator (again) = 3,1 fault code. Looking into the technical manual for the 1268 controller, they report the 3,1 fault code as: Fault {3,1} MAIN DRIVER OFF - Main contactor driver held high. Possible solutions: 1. Main contactor coil shorted. 2.New ALLTRAX XTC 48500 PDS controller Error code Electric EZGORemove the M- wire from terminal J9 on the Alltrax XCT48400-PDS, flip the Run/Tow switch to Run, turn the key on and check the blink codes. If the one green/one red isn't displayed, the problem isn't the controller. If it does still report the one green/one red error, the problem is in the controller.The single LED light on the controller is flashing 5,5 which according to Curtis means MAIN DROPOUT or Main Contactor Open or possible defective contactor. I replaced the solenoid with a heavier duty White Rodgers 48v solenoid hoping that was the problem. It is actually worse and will barely move.01-23-2022, 10:14 AM. # 1. dirtmann63. Not Yet Wild. Join Date: Jan 2022. Posts: 5. Bad Boy Buggy Controller Codes. I have a Bad Boy Buggy Classic that I recently bought. It has a green box with FSIP on the back w/ a silver box sitting on top with the following: 10-000523; BBB Classic; Field Retrofit Controller.Sep 15, 2017 · Re: Alltrax xct 400 pds blink codes. Seems the throttle is off a bit. XCT Control: B- to the small white wire in the 4pin plug on PDS cart. Just sitting there with everything powered should be 8-10V and at full pedal press 6-5V.Location: Charlotte, NC. Posts: 9,329. Re: Alltrax XCT 48400 Won't Power On. First, if You have a diode on the solenoid small posts, remove it (or at least make sure the polarity is correct). The original cart power 16ga red wire was "combo" crimped with the pack positive battery cable at the solenoid big post.Place the drive axle on jack stands— wheels off the floor. When working on wiring or batteries, always remove rings and watches and use the proper safety equipment, eye protection, and insulated tools. Disconnect batteries before installing or working on the controller. Advertisement.Programming Cable for the Alltrax AXE and DCX Controllers USB-RS232. $23.00. No reviews yet Write a Review. On Back Order. Add to Wish List. SKU: ACC-USB-RS232. Availability: Out of Stock.Controller is the alltrax sr48300. I bought kit from Scottyb. Last weekend I was driving at the lake a bIt then parked it. Came back about 30 mins later and nothing. ... Xct400 fault code- motor feild failure? Electric Club Car: pre charge fault code on 98 Nev: Electric Club Car: All times are GMT -5. The time now is 08:06 PM.I have a 2017 EZGO TXT 48v cart that was lifted and modified by a company called Trail Hog. I was told the Curtis SepEx Model 1268 Motor Controller was bad so I purchased a new one along with a new solenoid. The new controller and solenoid was installed and it ran good for about a day.Above 16 volts, the controller MAY be faulty. Separate the (6) six pin connector (only 4 are used) between the pedal box and the controller. If the voltage goes to 14-16 volts, the sensor is faulty. If the voltage remains below 14 or above 16 volts, the controller is faulty. RECONNECT the (6) six pin connector.Alltrax SR48500 Motor Controller for Yamaha G9/G14/G16 (0-1K) Golf Carts Series. $639.00. Free shipping. See all 9.Step 1: The easiest way to control a relatively low current 12-24V motor is by using a generic analog DC motor speed controller. This type of controller has a potentiometer to vary the speed of the motor. These controllers can be found with a wide range of power ratings. However, this type of controller is typically best for motors in the 5A to ...Alltrax XCT400, Pre-charge Failure. I recently installed an Alltrax XCT400 controller, SW180 solenoid (200 amp), and new cables all around on my late 90s EZGO TXT. Now that everything is installed, I'm getting a green with 6 reds on the status light, which the manual says is a pre-charge failure. If I switch it to tow and then run, the …ALLTRAX - Motor Controllers for the Electric Vehicle IndustryI got the specs for the controller which says 6 times flashing red means 'undervoltage'. I've tried all of Alltrax's recommended troubleshooting which is: Charge batteries. Load test batteries. Check voltage between controller B+ and B-. After doing this my cart still doesn't run. On top of that now the green LED doesn't turn on when I turn the ...Mar 3, 2019 · Ezgo txt alltrax spm48500ez throttle type troubleshooting: Electric EZGO: Swapping Alltrax AXE 7245 450a for Alltrax SR 72500 500a: Electric EZGO: Troubleshooting Alltrax Controller on DS Series Cart: Electric Club Car: DCX 400 troubleshooting help: Electric EZGO: Troubleshooting an Alltrax NCX300DCS: Electric EZGOProduct Bulletin 05 - E-Z-Go TXT 48V Cart and Alltrax Controllers Revision A, 8/17/2010. Download Bulletin. PRODUCT MANUALS. AXE Mini Manual Revision B, 12/02/2010 - Series Motor Controller. Download Manual. DCX Mini Manual Revision B, 12/10/2010 - Sep-Ex Motor Controller.Alltrax DCX400 Troubleshoot ??? I have an Alltrax DCX400PDS controller whereby the LED Green light does not turn off when the key is switched off. I have verified that the wiring is correct, etc. WIth the KS off and the Run/Maintenance switch in run the light gives 4 green flashes (ITS input) and then goes to a steady green with the key off or on.As long as you have continuity between F1 & F2 and A1 & A2 you are ok, any other combination of continuity is bad (F1 or F2 to the Case, A1 or A2 to the case, or any F to A combination is bad) you can disconnect the motor from the controller (make sure the battery pack is disconnected first) add a jumper to the motor and hook up a 12 volt battery charger to the motor, as long as it spins, your ...Electronic phase protector is used to protect compressor motors or other three phase motors from voltage faults. Expert Advice On Improving Your Home Videos Latest View All Guides ...Alltrax ToolKit software for SPM, SPB, XCT & SRX controllers. Features : ED Status Indicator: The LED located on the front of the unit provides status of the units operation and. used for troubleshooting. The LED Blink Codes occur at power up, the number of green blinks indicates the. throttle configuration: 1 Green LED flash = 0-5 kohm resistive.Page 1 6 Green = Taylor-Dunn 6-10.5V Mini-Manual Alltrax reserves the right to repair or replace merchandise at its option at 7 Green = CLUBCAR 5K-3-wire no cost to the customer, except for shipping costs of sending the defect For Golf Car Applications item to Alltrax.; Page 2 BATT puter and the controller which could damage Working on electric vehicles, sudden unex- FUSE both the AXE ...Key Features: Thermal plastic enclosure ABS. 36 or 48 volt models. 300, 400 or 500 amp models. Standard connectors for Club Car, EZGo, Yamaha G19/G22 and YDRE. Flexible USB programming. Integrated heatsink mounts on any suitable surface. Solenoid Control Output for "Main DC Contactor Control". Universal-Mount for no drill install included ...Car fault codes, also known as diagnostic trouble codes (DTCs), are an essential aspect of modern vehicle technology. These codes provide valuable insights into potential issues wi...How to program Alltrax XCT controller. Alltrax XCT 500 settings. RXV Curtis settings. First, you need to test the power. Connect the negative probe to the M terminal and the positive probe to the B+ terminal. Make use of the accelerator to check the controller. Press the accelerator to see the voltage increase.Alltrax code 2 red flashes? Electric EZGO. Electric EZGO Electric EZ GO Marathon, Medalist, TXT and RXV.This kit includes 2 500 amp Alltrax controllers, 1 Bluetooth module for wirelessly connecting to your controllers, 1 wire harness adaptor to connect your existing BBB wire harness to our controller system, and a mounting bracket to mount to you BBB cart. procedure and replacement equipment performed. May 2010.PRODUCT BULLETINS. Product Bulletin 01 – USB to Serial Adapter Windows-Vista. Revision A, 3/01/2007. Download Bulletin. Product Bulletin 02 – DCX Controllers Beeping once after throttle off event. Revision A, 8/28/2008. Download Bulletin. Product Bulletin 04 – ClubCar i2 Cart and Alltrax Controllers.Advertisement. Download this manual. Alltrax XCT Adapter Wire Kit for Function Knob Boxes: FN2 and FNKS. YAMAHA G19, G22 (called the GMAX) with 23 pin Controller. The Alltrax OEM 23 pin controller uses this same kit! File: DOC105-002-A_Install Doc, FN Knob Box YAM-G19 to XCT.pdf, Released Rev A, EC-051216.A Detroit Diesel fault code indicates a specific problem with a Detroit Diesel Series 60 engine. The fault code is displayed when the “check engine” light is activated on a truck p...Sep 10, 2009 · Re: Alltrax fault code 5 The controller is capable to push the motor to higher RPM's and if the bearing was bad, then this could be the cause of all that. When putting this controllers on 4+ fleet carts, always replace motor bearing and check brushes and replace if the are under 50% of their life.Below is the test procedures and results for all Alltrax controllers. OEM Curtis controller. tests attached below. Results should be as follows: DCS and Series carts have a signal range of 0.4-0.6v through 1.5-1.7v PDS carts have a signal range of 1.0v (+/- 0.3v) through 2.7v (+/- 0.5v) Throttle Voltage Check With Alltrax ControllersGroup 2: 2-Green + Red alarm code is a condition that may inhibit or cause the controller to stop, but is not a hard fault, rather a condition that requires attention. Group 3: 3-Green + Red alarm code is an uncalibrated throttle, clear the throttle calibration and try again. The program may also have a fault or loaded or updated incorrectly.Pack is at 48-49v -I have not charged it since returned home, plan on charging it tonight. Low voltage cut off is set around 20v so this is not the problem. I plugged the computer into the alltrax controller (sr48500) and it is communicating fine, responding to the throttle input, and everything else seems normal- NO ERROR CODES.DC motor controller for series and permanent magnet motors. ABS + PC510 flame resistant thermal plastic enclosure. All copper heat sinks. Sealed epoxy UL-94-VO / 5VA flame rating (best in industry) Adjustable undervoltage cutback 8-60 VDC. Adjustable overvoltage shutdown 22-90 VDC. Operating Frequency: 18k Hz.Controller is not powering up (No LED) Check for voltage on the wire attached to the RED J1 terminal. Verify wiring to the J1 terminals are correct Call Alltrax Tech Support LED blinks 1 green and 1 red Short Circuit/Output Fault Check B+, B- and M- connections on controllerRe: Troubleshooting an Alltrax NCX300DCS. Check the voltage of the pack and each battery. Ideally 12 hours after a charge, but a bad battery should show up regardless. Each battery should be within .1 volts of the others. Just 'cause they're new, doesn't mean they're good.On power up, the controller will blink out a throttle code and then a Status or Error Code (see below) Throttle codes: 1 Green LED Flash = 0-5k throttle 2 Green LED Flash = …Page 1 Solid Red: Controller in programming mode may be rejected. Mini-Manual Alltrax reserves the right to repair or replace merchandise at its option at Solid Yellow: Controller throttle is wide no cost to the customer, except for shipping costs of sending the defect open, controller is supplying max output, For Stock PDS &...Page 1 Solid Red: Controller in programming mode may be rejected. Mini-Manual Alltrax reserves the right to repair or replace merchandise at its option at Solid Yellow: Controller throttle is wide no cost to the customer, except for shipping costs of sending the defect open, controller is supplying max output, For Stock PDS &...ALLTRAX Controller offerings and speed controller upgrades for all golf cart makes and models! Free shipping. We price match. Shop new golf cart accessories today! Sign in or Create an account Contact Us; H: 8am-6pm EST, Mon-Fri. 1 844-422-7884. View Cart 0 0.00 USD. Checkout; Toggle menu. View Cart 0 0 ...Error code display:# of RED blinks. indicates any error conditions that might. exist: 1 Red = Throttle Position Sensor Over. Range. Check for open wires. 2 Red = Under Temperature. Controller.Hi all. I have listed what's on my cart below. I'm just wondering if any of you are running an Alltrax SR48500 controller on a Club Car DS. I currently finished getting a new build running thanks to a lot of help here! My red hawk motor is rated at 10 peak horse power. The Alltrax is a 500amp programmable controller. I'm seeing about 20 mph on ...REST APIs use the Status-Line part of an HTTP response message to inform clients of their request’s overarching result. RFC 2616 defines the Status-Line syntax as shown below: Status-Line = HTTP-Version SP Status-Code SP Reason-Phrase CRLF. HTTP defines these standard status codes that can be used to convey the results of a …Pack is at 48-49v -I have not charged it since returned home, plan on charging it tonight. Low voltage cut off is set around 20v so this is not the problem. I plugged the computer into the alltrax controller (sr48500) and it is communicating fine, responding to the throttle input, and everything else seems normal- NO ERROR CODES.Alltrax SR48300 Low voltage error in reverse Electric EZGOElectric EZGO Electric EZ GO Marathon, Medalist, TXT and RXV.Okay so I was able to find out that I may have a programming issue! So after connecting to a laptop I found that when they programmed it they set the controller as if it was apparently going to be hooked to 48v because the under voltage was set too high for a 36v cart.DS IQ new Alltrax fault code. Electric Club Car. Electric Club Car Electric DS, and Precedent golf carsProduct Features. 30-60 VDC (48V models) (60VDC MAX) Control Voltage range: KSI, Throttle Reverse inputs. Control voltage range; Key Switch (KSI), Throttle and Reverse inputs: 24-48 VDC, 60 VDC Max. Reverse Input: 50mA sink max. Standby Current (Powered Up):Yesterday, I installed a new Alltrax SPM 48500 controller, heavy duty solenoid, heavy duty f/r switch, D&D 170-010-0002 speed and torque motor, and heavy duty cables. I powered the cart up after installing everything and the cart didn't move an inch. I looked at the controller and noticed the Led indicator light was blinking 2 green lights ...Jul 8, 2019 · Okay so I was able to find out that I may have a programming issue! So after connecting to a laptop I found that when they programmed it they set the controller as if it was apparently going to be hooked to 48v because the under voltage was set too high for a 36v cart.Custom Motor Master List. Custom Built Series. Yamaha 36 Volt. 36 Volt Torque Venom *TOP SELLER*. 36 Volt Torque & Speed Coyote *TOP SELLER*. 36 Volt Torque & Speed Cyclops. 36 Volt Torque & Speed Grey Wolf. Yamaha 48 Volt. 48 Volt Torque Ganglord *TOP SELLER*.Electric Club Car Electric DS, and Precedent golf cars Electric DS, and Precedent golf carsThe throttle code blinks on controller power up and alarm codes blink when the alarm happens. All alarms are self clearing so when the alarm event is over, the controller resumes normal operation, except for the Short Circuit alarm that needs a power off cycle to clear the alarm. throttle codes: 1 Green LED Flash = 0-5k throttleRe: Alltrax NCX300 vs DCX300 controller. Not sure which beach your are at but Plum Quick could probably fix/upgrade your motor. As for the NCX vs DCX, the DCX is I think $30 more and has the advantage of tweaking it if needed. It also would allow you to put it in another cart in the future with the correct adapter.CAUSE - Noise entering the controller through the "SmartPort" wiring or it is wired incorrectly.. SOLUTION - A few steps are necessary to determine cause of "Err" message.. 1. Check SmartPort ® Wiring. If the "Err" message is displayed without a device attached, check that SmartPort ® wiring is correct. Make sure that the SmartPort wiring is not bundled with the field wiring.I have an Alltrax SPM 72400 and was having troubles with it. All I get is a single blinking green LED light. The single blink indicates a 0-5k throttle. I tried to clear and reset the throttle but the controller LED …Controller is not powering up (No LED) Check for voltage on the wire attached to the RED J1 terminal. Verify wiring to the J1 terminals are correct Call Alltrax Tech Support LED blinks 1 green and 1 red Short Circuit/Output Fault Check B+, B- and M- connections on controllerRepaired Controller + 1st eGator = 3,1 fault code. Running Controller + 1st eGator (again) = 3,1 fault code. Looking into the technical manual for the 1268 controller, they report the 3,1 fault code as: Fault {3,1} MAIN DRIVER OFF - Main contactor driver held high. Possible solutions: 1. Main contactor coil shorted. 2.Custom Motor Master List. Custom Built Series. Yamaha 36 Volt. 36 Volt Torque Venom *TOP SELLER*. 36 Volt Torque & Speed Coyote *TOP SELLER*. 36 Volt Torque & Speed Cyclops. 36 Volt Torque & Speed Grey Wolf. Yamaha 48 Volt. 48 Volt Torque Ganglord *TOP SELLER*.Location: Southern California. Posts: 73,453. Re: Alltrax controller - no status light. Not sure anything should click until the pedal is depressed. If a solenoid or SW202 clicks with the key then it can be left ON when the cart is not in use and will burn out. Back to square 1. 3 grn blinks indicates 0-5v throttle.Alltrax Inc PO Box 510 Murphy, OR 97533 Phone: 541-476-3565 Send requests and comments to: [email protected]Location: Southern California. Posts: 73,453. Re: Alltrax controller - no status light. Not sure anything should click until the pedal is depressed. If a solenoid or SW202 clicks with the key then it can be left ON when the cart is not in use and will burn out. Back to square 1. 3 grn blinks indicates 0-5v throttle.Model: DCX300 / DCX400 / DCX500 / DCX600. Type: Separately Excited (Shunt) DC motor controller. Battery Input Voltage: 24 – 48VDC Nominal, (60VDC max) Under voltage cutback: adjustable, 16-30 VDC. Over …. DC motor controller for separately excited motors (not serAllTrax 48500 SR Current Limit Electric EZGO. Type: Series Motor Controller Operating Frequency: 18kHz Controller Voltage, KSI & Reverse: SR48XXX 12-48V nom, 62V max SR72XXX 12-72V nom, 90V max Controller Operating Temp:-20°C to 75°C, shutdown @ 85°C ... ALLTRAX www.alltraxinc.com . Created Date: 10/24/2017 10:59:22 AM ... Now, when it comes to the blink codes, these are 300 isn't much. What cart, controller, motor are you posting about?prograMMing The ConTroLLer 29 BLink Codes 30 WarranTy sTaTeMenT 33 ... The fuse must be rated for pack voltage and fault current. 12 XCT OPERATORS MANUAL Wiring Controller Min. Wire AWG Standard Duty Min. Wire AWG ... system to allow for faster installation of Alltrax Controllers. Using the original mounting holes, the adapter plate … Controller is not powering up (No LED) Ch...

Continue Reading